CMS-Flow Hydrodnamics: Variable Definitions: Difference between revisions

From CIRPwiki
Jump to navigation Jump to search
No edit summary
No edit summary
Line 12: Line 12:
:<math>\tilde{u_i}</math> =  wave (oscillatory) velocity [m/s]with wave-average <math>\bar{\tilde{u_i}} = 0</math> below the wave trough
:<math>\tilde{u_i}</math> =  wave (oscillatory) velocity [m/s]with wave-average <math>\bar{\tilde{u_i}} = 0</math> below the wave trough


:<math>u_i^'</math> = turbulent fluctuation with ensemble average <math>\langle u_i^' \rangle</math> = 0 and wave average <math>\bar{u_i^'}</math> = 0 [m/s]
:<math>u_i^'</math> = turbulent fluctuation [m/s] with ensemble average <math>\langle u_i^' \rangle</math> = 0 and wave average <math>\bar{u_i^'}</math> = 0  


The wave-averaged total volume flux is defined as
The wave-averaged total volume flux is defined as


{{Equation|
{{Equation|
<math> h V_i = \overline{{\int_z^\eta} {u_i dz }}</math>
<math> h V_i = \overline{{\int_{z_b}^\eta} {u_i dz }}</math>
|2}}
|2}}


Line 24: Line 24:
:<math>h</math> = wave-averaged water depth <math>h=\bar{\eta} - z_b </math> (Figure 2-1) [m]
:<math>h</math> = wave-averaged water depth <math>h=\bar{\eta} - z_b </math> (Figure 2-1) [m]


:<math>V_i</math> = total mean mass flux velocity or simply total flux velocity for short [m/s]
:<math>V_i</math> = total mean mass flux velocity or simply total flux velocity [m/s]


:<math>\eta</math> = instantaneous water level with respect to the Still Water Level (SWL) [m]
:<math>\eta</math> = instantaneous water level with respect to the Still Water Level (SWL) [m]
Line 37: Line 37:
<math>hU_i = \int^\bar{\eta}_{z_b} \bar{u_i}dz</math>|3}}
<math>hU_i = \int^\bar{\eta}_{z_b} \bar{u_i}dz</math>|3}}


where <math>U_i</math> is the depth-averaged current velocity.
where <math>U_i</math> is the depth-averaged current velocity. Similarly, the wave volume flux is defined as by  
 
Similarly, the wave volume flux is defined as by  
{{Equation|
{{Equation|
<math>Q_{wi} = hU_{wi} = \overline{\int_{\eta_t}^\eta \tilde{u_i} dz}</math>
<math>Q_{wi} = hU_{wi} = \overline{\int_{\eta_t}^\eta \tilde{u_i} dz}</math>

Revision as of 19:56, 12 January 2015


The instantaneous current velocity ui is split into:

 

(1)

in which

= current (wave-averaged) velocity [m/s]
= wave (oscillatory) velocity [m/s]with wave-average below the wave trough
= turbulent fluctuation [m/s] with ensemble average = 0 and wave average = 0

The wave-averaged total volume flux is defined as

 

(2)

where

= wave-averaged water depth (Figure 2-1) [m]
= total mean mass flux velocity or simply total flux velocity [m/s]
= instantaneous water level with respect to the Still Water Level (SWL) [m]
= wave-averaged water surface elevation with respect to the SWL (Figure 2-1) [m]
= bed elevation with respect to the SWL (Figure 2-1) [m]


The total flux velocity is also referred to as the mean transport velocity (Phillips 1977) and mass transport velocity (Mei 1983). The current volume flux is defined as

 

(3)

where is the depth-averaged current velocity. Similarly, the wave volume flux is defined as by

 

(4)

where

= depth-averaged wave flux velocity [m/s]
= wave trough elevation [m]


Therefore the total flux velocity may be written as

 

(5)

Documentation Portal