Flow over a bump
Jump to navigation
Jump to search
UNDER CONSTRUCTION
Setup
The spatial domain consists of a rectangular
(1) |
where is the bed elevation and is the horizontal distance.
Table 1. General Settings for Flow over a Bump
Parameter | Value |
Discharge | 0.18 m^3/s |
Downstream water level | 0.33 m |
Bottom friction | None |
Model Setup
The computational domain is 25 m long and has a constant grid resolution of 0.1 m. A flux boundary condition is specified at the inflow boundary and a constant water level boundary condition is applied to the downstream boundary. An adaptive time between 0.1-10 seconds is applied.
Results
Table 2. Goodness of fit statistics for the water surface elevation
Statistic | Value |
RMSE | 0.0074 m |
RMAE | 0.0068 m |
R^2 | 0.991 |
Bias | 0.0017 m |
References
- Caleffi, V., Valiani, A., and Zanni, A. (2003). "Finite volume method for simulating extreme flood events in naturalchannels," Journal of Hydraulic Research, 41(2), 167-177.