CMS-Flow Bottom Friction

From CIRPwiki
Jump to navigation Jump to search
The printable version is no longer supported and may have rendering errors. Please update your browser bookmarks and please use the default browser print function instead.

Bottom Friction Dataset

Overview

The bottom roughness is specified using the Manning's n coefficient. The option is provided to use a roughness height, or bottom friction coefficient in addition to the Manning's coefficient. The bottom roughness is specified in the Bottom Friction Dataset section of within the Input tab of the CMS-Flow Model Control window (see Figure 2). The Bottom Friction Dataset is specified at every computational (ocean) cell and is required for each model simulation. Users may edit each grid to specific areas in the shoreline and bottom areas in the ocean.

Figure 1. Dataset Toolbox>Math>Dasta Calculator to create the bottom friction dataset.



Creating

Figure 2.4. Creation of ManningsN dataset. This process can be applied to create also Bottom Friction and Roughness Height Coefficients

Each time a new CMS-Flow simulation is created a bottom friction (roughness) dataset needs to be created using the Data main menu, 'Dataset toolbox'. The bottom friction parameter (related to Manning ) is spatially varying (cell-specific) over the grid domain or constant. At times a user may desire to represent locations where added friction is needed due to structures or increased turbulence due to sharp changes in current speed. More information on using this feature of CMS-Flow can be found here.


Figure 3. Three SMS Project Explorer showing the Manning's n, Bottom Friction Coefficient and Roughness Height datasets.

Once the Bottom Friction Dataset is created and the CMS-Flow Model Control window closed, a new auxiliary dataset will appear in the SMS Project Explorer (see Figure 3). Table 1. shows a list of the CMS cards related to the bottom friction datasets.


Table 1. SMS Cards related to the bottom friction datasets

Card Arguments Default Range Description Versions
USE_WALL_FRICTION CHARACTER ON ON | OFF Turns on or off wall friction >=3.5
MANNING_N_DATASET CHARACTER CHARACTER [<grid file>] [<grid name>//"Datasets/ManningsN"] none Grid file name and dataset path for the input Manning's n dataset >=v3.5
BOTTOM_FRICTION_COEF_DATASET CHARACTER CHARACTER [<grid file>] [<grid name>//"Datasets/BottomFricCoef"] none Grid file name and dataset path for the input bottom friction coefficient dataset >=v4.0
ROUGHNESS_HEIGHT_DATASET CHARACTER CHARACTER [<grid file>] [<grid name>//"Datasets/RoughnessHeight"] none Grid file name and dataset path for the input roughness height dataset >=v4.0


Editing

Figure 4. Manning n contours after modifying the areas under all three bridges.

Bottom roughness datasets may be edited manually, using the Data Calculator or by interpolating from a scatter set. Figure 4 shows an example where the Manning's n coefficient is increased for Shark River Inlet to account for the presence of vertical piles.

To interpolate bottom roughness data from a scatter set


Exporting

Exporting the bottom roughness (friction) datasets is useful for creating different project alternatives or when switching from different bottom roughness datasets types such as from Manning's n to Bottom Friction Coefficient and back. It is also useful for scripting multiple runs with different project alternatives.

Figure 5. Manning n contours after modifying the areas under all three bridges.
Figure 6. Exporting the Bottom Friction Coefficient to an XMDF file.


Advanced Cards

Table 2. Advanced Cards related to the bottom friction (roughness) dataset

Card Arguments Default Range Description CMS Versions
MANNING_N_CONSTANT real number none >=0.0 Specifies a constant input Manning's n coefficient. Over-rides any previous bottom friction cards. >=v4.0
BOTTOM_FRICTION_COEF_CONSTANT real number none >=0.0 Specifies a constant input Bottom Friction Coefficient. Over-rides any previous bottom friction cards. >=v4.0
ROUGHNESS_HEIGHT_CONSTANT real number none >=0.0 Specifies a constant Roughness Height in m. Over-rides any previous bottom friction cards. >=v4.0


Wall Friction

Figure 6. Wall friction specification in the SMS 11.0 CMS-Flow Model Control window.

The wall friction enhances the flow drag perpendicular to any dry boundary. The wall friction may be turned On or Off in the Flow tab of the CMS-Flow Model Control window (see Figure 7). The default in SMS is for the wall friction to be ON. Table 3 shows the CMS card used activating the wall friction.

Table 3. SMS Cards related to the bottom friction datasets

Card Arguments Default Range Description Versions
USE_WALL_FRICTION CHARACTER ON ON | OFF Turns on or off wall friction >=3.5


Wave-enhanced Bottom Friction (Advanced)

In the presence of waves, the mean (short-wave averaged) bottom shear stress which is used in the momentum equations is enhanced. There are 5 different options in CMS for estimating the wave-enhanced bottom friction. The default is a simple quadratic formula but can be changes using the Advanced Card described in Table 3.

Table 3. Advanced Card used for specifying the wave-current mean stress formulation

Card Arguments Default Range Description CMS Versions
WAVE-CURRENT_MEAN_STRESS CHARACTER W09 W09 | DATA2 | DATA13 | F84 | HT91 Defines the model used for calculating the mean bottom shear stress used in hydro >=4.0
WAVE_BOTTOM_FRICTION_COEFFICIENT REAL 0.5 0.3-0.7 Wave bottom friction coefficient used for quadratic combined wave-current mean bed shear stress calculation. >=4.0


Bed Slope Friction Factor (Advanced)

The bed slope friction factor accounts for the increased surface area over sloping beds as compared to the horizontal area. This feature may be turned On or Off through the Advanced Card described in Table 4.

Table 4. Advanced Card used for activating the bed slope friction factor

Card Arguments Default Range Description CMS Versions
BED_SLOPE_FRICTION_FACTOR CHARACTER OFF ON| OFF Specifies whether to include the bed slope friction factor or not in the calculation of the bed friction >=4.0


Documentation Portal