CMS Surface Roller: Difference between revisions

From CIRPwiki
Jump to navigation Jump to search
(Created page with "The surface roller model is run after each CMS-Wave and before each CMS-Flow run. It runs on the wave grid but is a separate model and module within the CMS. The surface roller m...")
 
(Created page with The surface roller model is run after each CMS-Wave and before each CMS-Flow run. It runs on the wave grid but is a separate model and module within the CMS. The surface roller m...)
Line 2: Line 2:


'''Table 1. CMS-Flow cards related  to the surface roller'''
'''Table 1. CMS-Flow cards related  to the surface roller'''
{| border="1"
{| border=1
! Card !! Arguments  !! Range !! Default !! Description  
! Card !! Arguments  !! Range !! Default !! Description  
|-
|-
| CALC_ROLLER ||  CHARACTER || ON <nowiki>|</nowiki> OFF || OFF || Turns on or  off the surface roller model in CMS.
| CALC_ROLLER ||  CHARACTER || ON nowiki|/nowiki OFF || OFF || Turns on or  off the surface roller model in CMS.
|-
|-
| ROLLER_DISSIPATION_COEFFICIENT || REA || 0.1 || 0.05-0.15 || Roller dissipation coefficient.  
| ROLLER_DISSIPATION_COEFFICIENT || REA || 0.1 || 0.05-0.15 || Roller dissipation coefficient.  
Line 11: Line 11:
| ROLLER_EFFICIENCY_COEFFICIENT ||  REAL || 1.0 || 0.5-1.0 || Roller efficiency coefficient.  
| ROLLER_EFFICIENCY_COEFFICIENT ||  REAL || 1.0 || 0.5-1.0 || Roller efficiency coefficient.  
|-
|-
| ROLLER_SCHEME || CHARACTER || UPWIND1 <nowiki>|</nowiki>UPWIND2 <nowiki>|</nowiki> LAX || UPWIND1 || Determines the  numerical scheme used for the surface roller calculation. UPWIND1 is a first order upwind scheme, UPWIND2 is a second order upwind scheme, and LAX is the second order Lax scheme.
| ROLLER_SCHEME || CHARACTER || UPWIND1 nowiki|/nowikiUPWIND2 nowiki|/nowiki LAX || UPWIND1 || Determines the  numerical scheme used for the surface roller calculation. UPWIND1 is a first order upwind scheme, UPWIND2 is a second order upwind scheme, and LAX is the second order Lax scheme.
|}
|}

Revision as of 18:32, 21 January 2011

The surface roller model is run after each CMS-Wave and before each CMS-Flow run. It runs on the wave grid but is a separate model and module within the CMS. The surface roller model parameters are set within the CMS-Flow cmcmards for convenience. For more information on the surface roller model see the Surface Roller Technical Documentation.

Table 1. CMS-Flow cards related to the surface roller

Card Arguments Range Default Description
CALC_ROLLER CHARACTER /nowiki OFF OFF Turns on or off the surface roller model in CMS.
ROLLER_DISSIPATION_COEFFICIENT REA 0.1 0.05-0.15 Roller dissipation coefficient.
ROLLER_EFFICIENCY_COEFFICIENT REAL 1.0 0.5-1.0 Roller efficiency coefficient.
ROLLER_SCHEME CHARACTER /nowikiUPWIND2 nowiki|/nowiki LAX UPWIND1 Determines the numerical scheme used for the surface roller calculation. UPWIND1 is a first order upwind scheme, UPWIND2 is a second order upwind scheme, and LAX is the second order Lax scheme.