CMS-Flow Model Parameters

From CIRPwiki
Jump to navigation Jump to search
Figure 1. CMS-Flow Model Control : Model Parameters tab for specifying time series output of CMS-Flow calculated datasets.

All of the CMS-Flow model parameters, settings, and output options are controlled from the CMS-Flow Model Control window (Figure 1). The window has several tabs including the Model Parameters tab in which most of the general settings are set for CMS-Flow. To open the CMS-Flow Model Control window, click on CMS-Flow | Model Control. The first tab will be the Model Parameters tab. The general parameters include solution scheme, time settings such as start time, duration and time step as well as wetting and drying depth. Most of the general parameters are set by going to "Model Parameters" tab within the "CMS-Flow Model Control" window. Below are some of the CMS cards related to the "Model Parameters" tab. Table 1 provides a brief description of some of the parameters in the tab and the associated CMS-Flow card used in the *.cmcards file.

Name Associated Card(s) Description
CALC_SEDIMENT_TRANSPORT CHARACTER OFF ON | OFF Turns on or off the sediment transport calculation.
Card Arguments Default Range Description
HYDRO_TIME_STEP REAL Calculated based on solution scheme and courant number none Sets to the time step for hydrodynamics in seconds.
DURATION_RUN REAL 48.0 >RAMP>0 Sets the duration of the model simulation in hours.
DURATION_RAMP REAL 1.0 Sets the length of the ramp period in which the model forcing is slowly ramped from zero.




Documentation Portal